Fire Alarm PH Fire Alarm PH

Contact Us

      • Philippines
      • 09171585060

      aa2000ent@gmail.com

 

         

          • firealarmph.mayaritech,biz
          • HOME
          • Services
            • Fire Protection System
              • STANDPIPE SYSTEM
              • FIRE PUMP
              • FIRE SPRINKLER
              • DELUGE SYSTEM
              • FOAM FIRE SUPPRESSION
              • KITCHEN FIRE SUPPRESSION
              • AEROSOL FIRE SUPPRESSION
              • WATER MIST SUPPRESSION
              • FIRE HYDRANT
              • FDAS FIRE ALARM
              • PORTABLE FIRE EXTINGUISHER
          • Products
            • Fire Detection Alarm System
              • EDWARDS*
              • NOTIFIER
              • SIMPLEX*
              • GAMEWELL BY HONEYWELL
              • ASENWARE
              • GST
              • TYY
              • HOCHIKI
              • HORING LIH
              • ESSER
              • BOSCH
              • COOPER
              • ORENA
              • HONEYWELL
          • BLOGS
          • Inquiry
          Fire Alarm PH Fire Alarm PH
          • HOME
          • Services
            • Fire Protection System
              • STANDPIPE SYSTEM
              • FIRE PUMP
              • FIRE SPRINKLER
              • DELUGE SYSTEM
              • FOAM FIRE SUPPRESSION
              • KITCHEN FIRE SUPPRESSION
              • AEROSOL FIRE SUPPRESSION
              • WATER MIST SUPPRESSION
              • FIRE HYDRANT
              • FDAS FIRE ALARM
              • PORTABLE FIRE EXTINGUISHER
          • Products
            • Fire Detection Alarm System
              • EDWARDS*
              • NOTIFIER
              • SIMPLEX*
              • GAMEWELL BY HONEYWELL
              • ASENWARE
              • GST
              • TYY
              • HOCHIKI
              • HORING LIH
              • ESSER
              • BOSCH
              • COOPER
              • ORENA
              • HONEYWELL
          • BLOGS
          • Inquiry
          Deluge Fire Protection Systems - AA2000 Philippines | Design, Installation & Maintenance

          DELUGE FIRE PROTECTION SYSTEMS

          Advanced deluge fire suppression technology for high-risk industrial applications. Protecting lives and assets across the Philippines with rapid response fire protection systems.

          NFPA Compliant BFP Approved 15+ Years Experience
          Deluge System Working Diagram

          Deluge System Operation Diagram

          What is a Deluge Fire Protection System?

          A deluge fire protection system is a water-based fire suppression system that uses open sprinkler heads connected to a piping system. Unlike traditional sprinkler systems, all sprinkler heads are open and the system is controlled by a deluge valve that releases water to all sprinkler heads simultaneously when activated.

          Key Characteristics

          Open Sprinkler Heads

          All sprinkler heads are permanently open, allowing immediate water discharge when the system activates.

          Simultaneous Activation

          Water is discharged from all sprinkler heads at once, providing complete area coverage.

          High-Volume Discharge

          Delivers large volumes of water quickly to suppress fires in high-hazard areas.

          Deluge Valve Control

          Controlled by a deluge valve that can be activated by fire detection systems or manually.

          Deluge System Components Diagram

          Deluge System Electric Actuation Diagram

          Deluge System Components

          Understanding the critical components that make up a reliable deluge fire protection system

          Deluge Valve

          The heart of the system that controls water flow to all open sprinkler heads. Available in pneumatic, hydraulic, or electric actuation.

          • • Quick opening mechanism
          • • Manual reset capability
          • • Pressure supervision

          Open Sprinkler Heads

          Specially designed open nozzles that provide optimal water distribution patterns for effective fire suppression.

          • • Various spray patterns available
          • • High-temperature resistant
          • • Corrosion-resistant materials

          Detection System

          Advanced fire detection components that trigger the deluge system including smoke, heat, and flame detectors.

          • • Smoke detectors
          • • Heat detectors
          • • Manual pull stations

          Piping Network

          Robust piping system designed to handle high water pressure and volume for effective fire suppression.

          • • Schedule 40 steel pipes
          • • Proper hangers and supports
          • • Drain and test connections

          Control Panel

          Centralized control and monitoring system for deluge valve operation and system status indication.

          • • System status indicators
          • • Manual activation controls
          • • Alarm and trouble signals

          Water Supply

          Adequate water supply system including pumps, tanks, and connections to ensure reliable operation.

          • • Fire pumps
          • • Water storage tanks
          • • Pressure maintenance

          Deluge System Applications in the Philippines

          Ideal for high-hazard areas where rapid fire spread is a concern and immediate large-volume water application is required

          Industrial Applications

          Petrochemical facilities and refineries
          Fuel storage and loading areas
          Flammable liquid storage
          Power generation facilities
          Chemical processing plants

          Commercial Applications

          Aircraft hangars
          High-value storage areas
          Stage and theater areas
          Critical equipment rooms
          Loading docks and platforms

          Why Choose Deluge Systems for Philippine Industries?

          Rapid Response

          Immediate activation covers entire protected area within seconds

          Complete Coverage

          Simultaneous discharge from all sprinklers ensures no fire escapes

          High-Risk Protection

          Designed for areas with fast-spreading fire hazards

          Professional Installation Process

          AA2000's systematic approach ensures proper deluge system installation for optimal performance

          Site Assessment & Design

          Comprehensive evaluation of fire hazards, building layout, and water supply requirements. Custom system design based on NFPA standards and local regulations.

          Permits & Approvals

          Obtain necessary permits from Bureau of Fire Protection (BFP) and other regulatory bodies. Ensure compliance with Philippine fire codes.

          System Installation

          Professional installation of deluge valve, piping network, open sprinkler heads, and detection systems by certified technicians.

          Testing & Commissioning

          Comprehensive system testing including hydrostatic pressure tests, flow tests, and functional testing of all components.

          Documentation & Training

          Complete documentation package including as-built drawings, operation manuals, and staff training on system operation.

          Installation Features

          Certified Technicians

          All installations performed by BFP-certified fire protection specialists

          Quality Materials

          Use of UL Listed and FM Approved components for reliability

          Timely Completion

          Efficient project management ensures on-time delivery

          Code Compliance

          Full compliance with NFPA, BFP, and local building codes

          Project Timeline

          Typical installation timeline: 2-6 weeks depending on system complexity and site conditions. Rush installations available for emergency situations.

          Maintenance & Emergency Support Services

          Ensuring your deluge system remains operational when you need it most

          Preventive Maintenance

          Monthly system inspections
          Quarterly deluge valve testing
          Annual full system testing
          Component replacement
          Detailed inspection reports

          24/7 Emergency Support

          Round-the-clock emergency hotline
          Rapid response service team
          Emergency repairs & troubleshooting
          Metro Manila & nationwide coverage
          2-hour response time in Metro Manila

          System Upgrades

          Technology modernization
          Smart monitoring integration
          Enhanced safety features
          Performance optimization
          Code compliance updates

          Frequently Asked Questions

          Common questions about deluge fire protection systems

          What is a Deluge Fire Protection System?

          A deluge system is a water-based fire suppression system that uses open sprinkler heads connected to a piping system. When activated, water flows through all sprinkler heads simultaneously, providing immediate and complete area coverage for high-hazard applications.

          How much does a Deluge System cost in the Philippines?

          Deluge system costs vary based on area coverage, hazard type, and complexity. Basic systems start from ₱500,000 for small areas, while large industrial installations can range from ₱2-10 million. Contact AA2000 for a detailed quote based on your specific requirements.

          Is Deluge System compliant with Philippine regulations?

          Yes, AA2000 designs and installs deluge systems in full compliance with Bureau of Fire Protection (BFP) requirements, NFPA standards, and local building codes. All installations include proper documentation and BFP approval coordination.

          When should I choose a deluge system over regular sprinklers?

          Deluge systems are ideal for high-hazard areas where rapid fire spread is expected, such as flammable liquid storage, aircraft hangars, or chemical processing areas. They provide immediate total coverage unlike traditional sprinklers that activate individually.

          How often does a deluge system need maintenance?

          Regular maintenance includes weekly visual inspections, monthly functional tests, quarterly deluge valve trip tests, and annual full system testing. AA2000 provides comprehensive maintenance programs to ensure system reliability.

          Do you provide 24/7 emergency support?

          Yes, AA2000 provides round-the-clock emergency support throughout the Philippines. Our emergency hotline (0917 158 5060) and email ([email protected]) are available 24/7 for urgent system issues or repairs.